For citation:
Aleshkin A. A., Bubnov Y. I., Protopopov V. K., Yagnyatinskii V. M. The fast method of the available capacity diagnostics of the lead-acid battery. Electrochemical Energetics, 2013, vol. 13, iss. 1, pp. 46-53. DOI: 10.18500/1608-4039-2013-13-1-46-53, EDN: RDMWLJ
The fast method of the available capacity diagnostics of the lead-acid battery
Present article describes the method of operative diagnostics of available capacity of the lead-acid accumulator (battery) at 10 or 20-h discharge mode. This method is developed on the basis of mathematical model of process of the discharge of the lead-acid accumulator. This allows calculating the available capacity of the accumulator (battery) on the basis of measurement of function of a response to the set short-term test signal without necessity of carrying out the control discharge of the battery. Calculation of available capacity is carried out on the basis of the parameter which is responsible for discharge capacity of the accumulator (battery), a total electric charge of an active surface of a limiting electrode.
1. Сухотин А. М. Справочник по электрохимии. Л.: Химия, Ленингр. отд-ние, 1981.
2. Дасоян М. А., Агуф И. А.. Основы расчёта конструирования и технологии производства свинцовых аккумуляторов. Л.: Энергия, Ленингр. отд-ние, 1978.
3. Эткинс П. Физическая химия: в 2 т. М.: МИР, 1980.
4. Алёшкин А. А., Сарапов С. В. // Фундаментальные проблемы электрохимической энергетики: материалы VII Междунар. конф. Саратов.: Изд-во Сарат. ун-та, 2008. С. 14–35.
5. Дасоян М. А., Агуф И. А. Современная теория свинцового аккумулятора. Л.: Энергия, Ленингр. отд-ние, 1975.